Search
Wish list
Region
Region (nl)
Products
Company
Focus on
Contact
de  en  pl  fr  hr  nl  hu  it  sv  sl  cn  es
Press and drag mouse button

Double wall insert

for setting in concrete

HSI150 K2/X

For the gastight and watertight connection on both sides of system seals for cables and cable ducts and maximum flexibility for subsequent use.

Single wall insert with plug-in socket

for setting in concrete and connecting smooth cable ducts

HSI150 GSM

Für den beidseitigen gas- und wasserdichten Anschluss von Systemabdichtungen für Kabel und Kabelschutzrohre und eine maximale Flexibilität bei der späteren Nutzung.

Polymer flange

for retrofit dowelling

HSI150 DFK

For retrofit dowelling via core drill holes or for screwing onto housings. Used for the gastight and watertight connection of system seals for cables and cable ducts.

Double wall insert

for setting in concrete

HSI90 K2/X

For the gastight and watertight connection on both sides of system covers for cables and cable ducts and maximum flexibility for subsequent use.

System cover

cable seal with hot shrink-fit method

HSI150 D WS

For use in wall insert and plastic flange HSI150. The thermal sleeves support a wide area of application, they are shrunk onto the cables by means of the application of heat from the system cover socket. Empty system cover sockets can be sealed with blind plugs.

Closing cover

for empty wall inserts and plastic flanges

HSI150 DT

For pressure-tight sealing of wall inserts that are not in use and plastic flange of the HSI150 system.

Insulated earthing entry

HEA IS

Specifically for station construction. Installed during formwork work. Earthing connections to the building can be made with the thread on both sides in the electrically isolated conductor core.

Double wall insert

for setting in concrete

HSI150 K2/X

For the gastight and watertight connection on both sides of system seals for cables and cable ducts and maximum flexibility for subsequent use.

Split system cover

for retrofit sealing

HSI150 DG

For use in wall insert and polymer flange HSI150. Split design for sealing new cables to be installed or cables that have already been laid.

Individual press seal

for micro pipes and empty conduits

HRD150 b60 A2/EPDM55

Individual press seal in a closed design to seal micro pipes or empty conduits.

Site power supply entry

for secondary substations

BD

Zur temporären Stromversorgung bzw. Notversorgung von Transformatorenstationen. Mit der Baustromdurchführung können Kabel während Baumaßnahmen oberirdisch in die Station eingeführt werden. Die Stationstüren können somit geschlossen werden.

SEGMENTO

Segments for installation in HSI150 S3 system cover

SEG

For particularly gentle sealing of micropipes and control lines.

 Close

Fire protection

The HSS fire barrier impresses by being highly flexible in planning and execution. It is also easy to retrofit and takes minimum effort to install. As well as meeting the requirements of fire resistance class S90 to DIN 4102-9, when combined with the HSI150 system seal or HRD press seal, the fire barrier is absolutely gastight and watertight. It is installed in HSI150 wall inserts or wall sleeves (included at planning stage) or in retrofitted core drills.

Fire protection

Fire Protection Kits from Hauff-Technik – Ideal for Your Building Introduction

Fire protection is vital in the field of building technology. Certain zones necessitate the implementation of fire stops. With the fire protection kits from Hauff-Technik, you can fulfill the strict construction guidelines for fire safety technology effectively. Our kits are designed for various application areas, emphasizing the diverse options available for fire stops.

Fire Protection Kits for Various Cable Entries and Application Scenarios

Multiple options exist for implementing building and cable entries, and Hauff-Technik provides tailored fire protection solutions for each type of entry. Typically, a fire protection kit consists of several flexible fire protection pillows, differing in size. Hauff-Technik kits include up to ten pillows across four distinct variants, ensuring optimal sealing for pipes and building entries, regardless of the number of cables being routed. Only the necessary pillows are utilized for effective sealing.

The Fire Protection Kit S90 exemplifies this concept. Specifically designed for fire protection in core drillings and conduit pipes, it excels in wall entries and all types of cable conduits. The kit is suitable for core drillings with diameters ranging from 70 to 300 mm, ensuring fire protection for empty, fully filled, or partially filled core drillings. The resulting fire stop is gas- and water-tight, forming fire protection barriers for core drillings and conduit pipes with a minimum thickness of 280 mm and compatible with walls having a thickness of at least 150 mm.

The Fire Protection Kit S90 works with HSI150 system covers to implement fire safety for building entries. Main supply lines are routed into buildings through system covers in conjunction with cable protection pipes. These kits allow for installation from one side, which is particularly beneficial for retrofits since the exterior is typically underground and inaccessible. This method achieves a minimum stop thickness of 440 mm, with wall thicknesses of at least 240 mm required for compatibility.

Additionally, fire protection kits can safeguard ring space seals, as they are compatible with various Hauff-Technik ring space seals like HRD150 or HRD160. The pillows are installed between the supply line and the ring space seal, achieving a minimum stop thickness of 280 mm, with the kits suitable for wall thicknesses starting from 150 mm.

All these solutions can be utilized with any type of media line, including water pipes and telecommunications cables. The use of fire protection kits with electrical lines is also possible. Furthermore, these kits are approved for all wall types. The installation is straightforward, requiring no additional wall structures. When using a system cover, the pillows are placed around the supply lines and then pushed into the cover, secured with stainless steel bands.

Thus, no special tools are needed for installing a fire protection kit. The entire installation process can be completed within minutes, and pillow installation can occur at any time, either during construction or later. Additionally, all fire protection pillows are weather-resistant, which is especially important for installations in ground areas.

Fire Protection Kits from Hauff-Technik Meet High Standards and All Common Regulations

The essential role of a fire stop is to halt the spread of fire or, at minimum, to prolong the process as much as possible. The placement of these fire stops is required at specific intervals, particularly where walls and doors are concerned. One of the key vulnerabilities in these systems arises from the service lines that run through the walls, such as power and telecommunications cables. Fortunately, targeted precautions are in place to tackle this issue. Consequently, Hauff-Technik offers fire protection kits suitable for ring space seals, cable introductions, and conduit openings. We also provide kits tailored for core drilling and similar scenarios.

Every one of our fire protection kits meets the requirements of the fire resistance class S90, indicating that they can endure flames for at least 90 minutes. As a result, these fire stops comply with the standards outlined in DIN 4102-9, which specifies the fire behavior of building materials and elements like cable seals. Additionally, the fire protection kits have received general building authority certification from the body responsible for the approval of construction products and types. With these installations, you can be confident that you are fulfilling all necessary fire safety regulations.